Line 5: Line 5:
 ===== Wideband Kit Outputs ===== ===== Wideband Kit Outputs =====
 Wideband kits typically have two different types of outputs. ​ In the wideband kit install notes, one output will be called something like "0-1v simulated narrowband"​ and the other will be called something like "0-5v analog wideband"​. ​ If you want to remove the factory front O2 sensor and use the WB's simulated output in its place, then both outputs will be used.  The narrowband signal will be connected to the ECU's front O2 input so that the ECU sees what it believes is a factory O2 signal on that pin.  The 0-5v analog wideband signal will be connected to [[ExternalSensorInput|another input pin]] on the ECU to be datalogged as a wideband signal. Wideband kits typically have two different types of outputs. ​ In the wideband kit install notes, one output will be called something like "0-1v simulated narrowband"​ and the other will be called something like "0-5v analog wideband"​. ​ If you want to remove the factory front O2 sensor and use the WB's simulated output in its place, then both outputs will be used.  The narrowband signal will be connected to the ECU's front O2 input so that the ECU sees what it believes is a factory O2 signal on that pin.  The 0-5v analog wideband signal will be connected to [[ExternalSensorInput|another input pin]] on the ECU to be datalogged as a wideband signal.
 +
  
  
Line 14: Line 15:
 The narrowband output is typically ranged from 0-1v and is only useful in providing the ECU with a simulation of a factory O2 sensor. ​ It does not generally serve as an acceptable wideband output because it's meant to switch abruptly between lean and rich around stoich just as the factory sensor does.  It's only purpose is to provide a replacement signal for the factory front O2 sensor if the factory O2 sensor is removed from the car. The narrowband output is typically ranged from 0-1v and is only useful in providing the ECU with a simulation of a factory O2 sensor. ​ It does not generally serve as an acceptable wideband output because it's meant to switch abruptly between lean and rich around stoich just as the factory sensor does.  It's only purpose is to provide a replacement signal for the factory front O2 sensor if the factory O2 sensor is removed from the car.
  
-**V3 NOTE**: Our latest ECMLink (V3) product offers a [[v3narrowbandsim|narrowband simulation function]] internal to the ECU, thus freeing up an additional logging input. ​ With that function, you simply run your wideband sensor'​s 0-5v analog output to the ECU and then configure ECMLink to do the simulation internally.+**V3 NOTE**: Our latest ECMLink (V3) product offers a [[v3narrowbandsim|narrowband simulation function]] internal to the ECU, thus freeing up an additional logging input. ​ With that function, you simply run your wideband sensor'​s 0-5v analog output to the ECU and then configure ECMLink to do the simulation internally.  This allows you to use only one input to the ECU (typically the front O2 input) to do both jobs for you (logging wideband A/F ratio and simulating narrowband operation for normal closed loop control).
  
 ==== 0-5v Analog Output ==== ==== 0-5v Analog Output ====
widebandbasics.1252574381.txt.gz ยท Last modified: 2009/09/10 05:19 by twdorris